METERING PRINCIPLES

03

3 .10 .8 Proving run (ball position)

C02: Rotate 4way

valve forward

C03: Valves

correctly

positioned ?

C19: Enough

pulses received?

C20: Run Completed

Succesfull

Yes

No

Yes

C01: Start Run

C04: Dectector

switch1 triggered

C05: Start counting

pulses

C06: Dectector

switch2 triggered

C07: Stop counting

pulses

C08: Wait for ball

to reach chamber

C10: Rotate 4way

valve reverse

C11\: Valves

correctly

positioned ?

Yes

C12: Dectector

switch2 triggered

C13: Start counting

pulses

C14: Dectector

switch1 triggered

C15: Stop counting

pulses

C16: Wait for ball

to reach chamber

No

C17: Calculate pulses

C18: Release all flow

control valves

C22: Run Completed

Un-Succesfull

C21: Release all flow

control valves

No

C09:

Run timer timeout

alarm active ?

Yes

No

Figure 18 Proving run flowchart