SUMMIT 8800

STREAM CONFIGURATION

06

Ultrasonic meter type

The specific meter to be used can be selected from a list. As meters are

generally designed for liquid, gas or stream, the list varies depending on

the medium. Also there is the option to use an analog input for flow.

Number of paths

The number of measurement paths (1 to 8) of the selected meter (see

meter specifications for details). Used when the meter communicates

serially. An alarm will be given if the meter is not configured for the same

number of paths.

Meter units

The engineering units in which the meter is measuring flow.

Maximum Counter

Increment

The maximum allowable increment for the flow data counter used for the

calculated volume. Used when the meter communicates serially. This

prevents a massive increment when, after a communication failure, the

meter resumes normal communication.

Flow offset

This is used to simulate flow during testing when no meter is available. In

theorie it could also be used to correct a fixed mis-match of the flow.

Meter specific data

For certain meters some parameters must be set. As these parameters

are meter specific, please consult the meter manufacturer’s operating

instructions for further guidance. Parameters for the following meters are

available:

- Flowsic 600

Use or ignore the security alarm, provided by Modbus or a digital output

- Senior Sonic

Dimensions and material of the meter and calculation of dynamic Viscosity

- Instromet QSonic

UFM efficiency settings used for reliability and diagnostic information.

- KROHNE UFM 3030

Select if the measured flow rate, velocity of sound and totals should be

used.

6 .2 .2 .2 Pulse Input API 5 .5 level B to E

Define the preference for serial or pulse input and the pulse input setting for API 5.5 level B to E

if used

Figure 69 Ultrasonic pulse input section for liquid and gas API 5 .5 Level B to E