SUMMIT 8800

RUN SWITCHING

07

7. Run switching

Liquid

Gas

Steam

7 .1 Introduction

Run switching (also known as meter run staging or tube switching) is a function that controls

the flow of fluid across multiple streams in a station. It normally is meant to optimize the ac-

curacy, and can be used for normal operation or during proving.

To use run switching, it must be turned on first, under the general section.

The main run switching parameters must then be set per stream that will be used with the func-

tion.

7 .2 General configuration

Under General, the run sitch function can be turned on:

Figure 125 Turn run switching on

There are two parameters:

Activate run switching

Turns the run switching on or off

Delay between moving

streams

To prevent continuous switching, a delay can be set after the conditions to

switch are present and before the actual switch command will be given.