STREAM CONFIGURATION

06

can be defined for the CO2 emission calculation.

TebaseCO2

Base temperature of CO2

MrCO2

Molecular mass CO2

ZnCO2

zn at base pressure and temperature

OF

CO2 oxidising factor

In case of gas ultrasonic meter, the selection for AGA10 speed of sound.

Figure 121 AGA 10 speed of sound

The AGA10 uses the composition, the temperature and the pressure to calculate the speed of

sound for an ultrasonic meter, The selection allows the comparison between the measured and

calculated speed of sound to verify the calibration of all components: meter, P, T and GC.

AGA10 calculation enabled

Calculation to be performed yes or no.

AGA10 SoS Acc deviation

Generates an accountable alarm when a deviation occurs

AGA10 SoS nAcc deviation

Generates an non-accountable alarm (warning) when a deviation

occurs.

6 .14 .1 Pipe constants

Liquid

Gas

Steam

All information related to the pipe details for steam application only:

• Pipe Data

• Saturation Pressure Constants

• Reynolds Constants

• Velocity of Sound Constants