3 .8 Stream, station and batch totals
A total for flow is calculated by multiplying the flow rate by the time difference between the cur-
rent and previous measurement. The SUMMIT 8800 keeps more than 25.000 different totals as a
combination of:
Qty Type total
Code used
2
Metric
The totals in metric units
USC
The totals in US customary units
2
Positive
+
Measured in positive direction
Negative
-
Measured in negative direction
11
Running totals
Totals until now
Current period 15 minutes
cqh.
Totals for the running15 minutes
Current period Hourly
ch.
Totals for the running hour
Current period Daily
cd.
Totals for the running day
Current period Monthly
cm.
Totals for the running month
Current period Quarterly
cq.
Totals for the running quarter
Previous period 15
minutes
pqh.
Totals for the previous 15 minutes
Previous period Hourly
ph.
Totals for the previous hour
Previous period Daily
pd.
Totals for the previous day
Previous period Monthly
pm.
Totals for the previous month
Previous period Quarterly
pq.
Totals for the previous quarter
9
Unhaltable
U
All product measured
Normal
N
Measured during normal
conditions
Error
E
Measured during error conditions
Maintenance
M
Measured during maintenance
Tariff level 1
t1
Measured when in tariff level 1
Tariff level 2
t2
Measured when in tariff level 2
Tariff level 3
t3
Measured when in tariff level 3
Tariff level 4
t4
Measured when in tariff level 4
Tariff level 5
t5
Measured when in tariff level 5
11
Pulse count
Pulses
The amount of pulses counted
Line volume
VLine
Line volume for the main pulse
Monitor volume
VMon
Line volume for the monitor pulse
Volume before
normalisation
Vbc
Volume after error curve
Volume after P/T
correction
Vbc
Volume after P and T correction
Normalised volume
VN
Normalised volume
Normalised volume net
VNnet
Net normalised volume (product