beautypg.com

6 .8 .3 solartron/sarasota transmitter – KROHNE Summit 8800 Vol 2 User Manual

Page 105

background image

105

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

Figure 99 Viscosity

6 .8 .3 Solartron/Sarasota transmitter

For each Solartron/Sarasota transmitter selected, an additional icon “ρtp sensor” will appear in

the left hand list:

Liquid

Gas

Steam

Liquid

Gas

Steam

The user will be required to enter the transducers calibration constants:

Figure 100 Density transducer parameters

For details on these parameters, please refer to the transducer calibration and instruction

manual.

The pressure and temperature at the density point must be also specified. Their selection is

almost identical to the stream pressure and temperature selection. Please note that in this case

only 2 pressure and temperature sensors are possible but that also the pressure and tempera-

ture at the meter can be used.