SUMMIT 8800

HARDWARE DETAILS

05

Figure 45 Setup of a meter with Hart in Hardware selection

In most case only one meter will be connected to one Hart loop, but up to 3 meters per loop

could be connected. Please note that the update time might be more than 1 second with multi-

ple meters as Hart is relatively slow.

5 .2 .1 .5 Differential pressure

For Orifice plate, Venturi, Nozzle or Cone Meter differential pressure will be measured, see

chapter 3.3.

Within the SUMMIT 8800, 1- 9 dP transmitters can be selected – 3x High, 3x Medium, and 3x Low

range. At least 1 High range transmitter is needed.

Figure 46 DP transmitter selection in Hardware input

The SUMMIT can handle Transmitters, which send out a Hart or analog (4-20mA) signal.