Using Probes

24

 

 

Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual

Connections Overview for Gen2 Multi-lead Probe

Use a 1‐pod or 2‐pod setup depending on the lane width of the recording:

For x16 recordings, use the 2‐pod setup. 

For all other lane width recordings, use a one‐pod setup.

For x8 and x16, use the straight iPass cables to connect the probe data connectors on the 
Analyzer to the pod(s). 

On the other side of the pod, connect the flexible lead tips.

Connection Procedure

To connect Summit T3‐16 to the System Under Test (host platform or root complex under 
test): 

1. Connect the pods to the Analyzer using the straight iPass cables.
2. Connect the flexible lead tips to the pods using the SSMP cables.
3. Connect the lead tips to the system under test by soldering to the trace.