beautypg.com

3 changing the value of the timer – Teledyne LeCroy Summit T3-16 PCIe Multi-lane Protocol Analyzer User Manual User Manual

Page 111

background image

    

Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual

99

Timer

 Teledyne  LeCroy

Figure 5.48: Starting and Resetting Global and Sequence State Timers

Note:

Listed below are some of the considerations to note about timer functionality

1. If a timer is reset, it will restore to it's original value, in this case the value defined by 

the user.

2. Resetting a timer will stop it and set it to it's original value.
3. Local timers for a particular state will automatically reset if the sequencer advances 

to another state. Example: "Timer A" in State 1 and "Timer A" in State 2 are different 
timers not related to each other.

4. Local timers are controlled by events defined in the same state where the timers are 

defined.

5. In case of competing actions to control global timers using the same event from 

global and local states, the control from local states takes priority.

5.23.3

Changing the Value of the Timer

To change the value of the timer (see

 Figure 5.49 on page 100

):

1. Right‐click on the Timer. 
2. Select Properties 
3. Enter in values for the Timer in the fields provides in Secs, Millisecs, Microsecs and 

Nanosecs on the Timer tab.