Teledyne LeCroy Summit T3-16 PCIe Multi-lane Protocol Analyzer User Manual User Manual
Page 115
Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual
103
Probe Settings
Teledyne LeCroy
To use the external reference clock or for quick calibration click the appropriate
checkboxes to select them. If checked, calibration routine will only scan CTLE, if not
checked it will include DFE with the CTLE scan which will take longer, approximately 9
minutes.
Figure 5.53: Calibrate Dialog
The calculated CTLE values are automatically displayed in the relevant lane field. Click
Save to save the settings or click Save As Default to save the settings as the default. Click
Load to save the settings as a .rec file as a PE Tracer Recording option to be used at a later
time. Click Reset to clear the settings.
The calculated CTLE values are automatically displayed in the relevant lane fields as
shown in Figure 5.54. Click Save to save the settings or click Save As Default to save the
settings as the default. Click Load to save the settings as a .rec file as a PE Tracer
Recording option to be used at a later time. Click Reset to clear the settings (see
Figure 5.54 on page 104
).