Extron Electronics DVS 510 Series User Guide User Manual
Page 83
DVS 510 Series • Remote Configuration and Control
77
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Event Control
View event buffer memory
27
E
X10$
,
X10%
,
X10^
,
X10&
E
}
X12)
]
Write event buffer memory
24,27
E
X10$
,
X10%
,
X10^
,
X10*
X10&
E
}
Evt
X10$
,
X10%
,
X10^
,
X10*
]
NOTE: The response to the Write Event command is padded with leading zeros for
X10$
and
X10^
.
X10$
= 5 digits;
X10^
= 10 digits.
Write string to event buffer
memory
24,27
E
string *
X10$
,
X10%
,
X10^
FE
}
Evt
X10$
,
X10%
,
X10^
,string
]
NOTES:
•
F
must be capitalized to read and write strings to event buffer memory.
•
The response to the
Write
String
command is padded with leading zeros for
X10$
and
X10^
.
X10$
= 5 digits;
X10^
= 10 digits.
•
The
Write String
command expects a string preceded by
E
. Strings returned by the device (read or write
response) are binary (non-escaped) data.
View string from event buffer
memory
27
E
X10$
,
X10%
,
X10^
,
X11)
FE
}
String
Start events
24,27
E
1AE
}
Ego
]
Stop events
24,27
E
0AE
}
Est
]
Query the number of events
running
E
AE
}
nnnnn
]
In Verbose Mode:
Enm
nnnnn
]
Response is a 5-digit number.
Telnet text responses:
event0 starting loc,
length
]
event1 starting loc,
length
]