Symbol definitions for ip-specific sis commands, Symbol definitions for ip-specific sis, Commands – Extron Electronics DVS 510 Series User Guide User Manual
Page 73
DVS 510 Series • Remote Configuration and Control
67
Symbol Definitions for IP-specific SIS Commands
•
=
Space
]
=
Carriage return with line feed
}
=
Carriage return with no line feed
|
=
Pipe (vertical bar) character. For URL-encoded commands, has the same function as ].
E
=
Escape
W
=
For URL-encoded commands, has the same function as
E
14, 24, 27, 28
= Superscripts indicate the error message displayed if the command is entered
incorrectly or with invalid parameters (see
” on page 50).
X!
= Input selection
1 through 10
X1)
= On and off
0 = Off or disable
1 = On or enable
X7!
= Port number
01–99 (represented as two ASCII characters with
leading zero if required)
X7@
= Command data section
Factory default name (model name
+ last 3 pairs of
MAC address)
X7#
= GMT offset
–12.0 through +14.0. Represents hours and minutes
offset from Greenwich mean time (GMT).
X8!
= Firmware version number
n.nn (listed to two decimal places)
X8@
= Unit name
Up to 24 characters: alphabetical (A–Z or a–z), digits
(0–9), or hyphen (-).
NOTES:
•
The following characters are invalid or not recommended in names:
{space} + ~ , @ = ` [ ] { } < > ‘ ’ “ ” ; : | \ and ?.
•
The first character must be alphabetical.
•
The last character must not be a hyphen.
X8#
= Local date and time format
For setting:
In the format MM/DD/YY•HH:MM:SS
MM = month: 10 (January) through 12 (December)
DD = 01 through 31
YY = 00 through 99
HH = 00 through 23
MM = 00 through 59
SS = 00 through 59
For reading:
In the format Day,•DD•Mmm•YYYY•HH:MM:SS:
Day = weekday: Mon through Sun
DD = 01 through 31
Mmm = month: (Jan through Dec)
YYYY = year: 2000 through 2099
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X8$
= IP address
nnn.nnn.nnn.nnn
(Leading zeros in each of the four fields are optional
for setting values and are suppressed in returned
values.)
Factory default IP address: 192.168.254.254
Default broadcast IP address: 255.255.255.255
X8&
= Time (in 10-ms increments) to wait 10 through 32767
for characters to arrive at a serial
Default = 10, or 100 ms
port before terminating the
connection