DVS 510 Series • HTML Configuration and Control 101

Picture Control

From the User Control screen, you can adjust the picture controls listed below.

NOTE: These controls are not available when the DVS is in PIP mode. To adjust picture

controls for the PIP window, click

PIP

Setup

on the left sidebar menu to use the

PIP Setup screen.

To adjust the picture controls in this section (except for

Pan

), either click the

+

or

button to

increase or decrease the value in the text field, or key in a value.

Horizontal

Shift

: Move the image to the right or left on the display. The value in

the text box is the distance in pixels of the left edge of the image from the left edge of
the window. The range is dependent on the output; the default is

0

plus or minus the

output rate. (This is the same as horizontal positioning or centering.)

Vertical

Shift

: Move the image up or down on the display. The value in the text box

is the distance in lines of the top edge of the image from the top edge of the display.
The range is dependent on the output; the default is

0

plus or minus the output rate.

(This is the same as vertical positioning or centering.)

Horizontal

Size

: Stretch or shrink the image horizontally. The value in the text box is

the width of the image in pixels. The range is dependent on the output rate.

Vertical

Size

: Stretch or shrink the image vertically. The value in the text box is the

height of the image in lines. The range is dependent on the output rate.

Color

: Adjust the intensity of the colors in the image. (At the lowest adjustment, all

colors appear as shades of gray.) The range is

000

through

127

; the default is

064

.

Tint

: Change the appearance of the colors in the selected window. The range is

000

through

127

; the default is

064

.

Brightness

: Set the black level of the input. The range is

000

through

127

; the default

is

064

.

Contrast

: Increase or decrease the range of light and dark values in the image. The

range is

000

through

127

; the default is

064

.

Detail

Filter

: Adjust the sharpness of the image. The range is

000

through

127

; the

default is

064

.

Zoom

: Increase or decrease the size of the image while keeping the aspect ratio

constant. The range is dependent on the output rate.

Pan

: Click the

L

or

R

button to move the focus on the image left or right. Click the

U

or

D

button to pan up or down. Pan is available only if Zoom is set to greater than 100%.

Input Sampling

The input sampling controls can be adjusted in the same manner as the picture controls:
either click the

+

or

button to increase or decrease the value in the text field, or key in a

value.

NOTE: These controls are not available when the DVS is in PIP mode. To adjust picture

controls for the PIP window, click

PIP

Setup

on the left sidebar menu to use the

PIP Setup screen.

Horizontal Start: Specify the distance in pixels from the left edge of the total video
display area of the selected input to the left edge of its active area. The default is

128

.

Vertical Start: Specify the distance in pixels from the top edge of the total video display
area of the selected input to the top edge of its active area. The default is

128

.