DVS 510 Series • Operation

36

Set IP Address submenu

Valid IP addresses consist of four 1-, 2-, or 3-digit numeric sub-fields (called “octets”) that
are separated by periods. Each octet can be numbered from 000 through 255 (leading zeros
are inserted by the DVS). The factory-installed default address is

192.168.254.254

, but if

this conflicts with other equipment at your installation, you can change the IP address to any
valid value via the Set IP Address screen.
To change the unit IP address:

1.

Press Next until the Set IP Address screen is displayed.

2.

Rotate the horizontal Adjust knob ({) to select an octet. (The selected octet flashes.)

3.

Rotate the vertical Adjust knob ([) to increase or decrease the flashing number.

Set Subnet Mask submenu

The subnet mask is used to determine whether the DVS is on the same subnet as the mail
server when you are using a subnet (see “

Subnetting, a Primer

” on page 120). The subnet

mask address has the same validity rules as the IP address. The default subnet mask is

255.255.000.000

.

To change the subnet mask:

1.

Press Next until the Set Subnet Mask screen is displayed.

2.

Rotate the horizontal Adjust knob ({) to change the flashing octet selection.

3.

Rotate the vertical Adjust knob ([) to increase or decrease the flashing number.

Set Gateway Addr submenu

The gateway address identifies the gateway to the mail server that will be used if the
scaler and the mail server are not on the same subnet. The default gateway address is

000.000.000.000

.

To change the gateway address:

1.

Press Next until the Set Gateway Addr screen is displayed.

2.

Rotate the horizontal Adjust knob ({) to change the flashing octet selection.

3.

Rotate the vertical Adjust knob ([) to increase or decrease the flashing number.

NOTE: The Edit Comm Settings menu has no MAC address screen, because the MAC

address cannot be changed.

Exiting the Menu System

To exit the menu system, press the Menu button repeatedly until the

Exit

Menu?

Press

NEXT

screen appears. Press the Next button to return to the default cycle.

Alternatively, wait until the menu system times out and the default cycle resumes
(approximately 30 seconds).

Picture Controls

The DVS has six picture control buttons located on the front panel to the right of the PIP
buttons. You can use these buttons to adjust size, position, brightness and contrast, color
and tint, detail, magnification (zoom), and select a portion of the image on which to
focus the view (pan). (See the

Picture Controls Summary

table on the next page for an

explanation of these button functions.)

NOTE: When PIP mode is active, all these picture controls apply to the PIP window. To

configure the main window, press the PIP On/Off button to exit PIP mode.