DVS 510 Series • Operation

34

View Comm Settings Menu

The View Comm Settings menu lets you view the current settings for the communication
ports, including the IP, subnet mask, and gateway addresses of the unit, the MAC (Media
Access Code or hardware) address, the Dynamic Host Configuration Protocol (DHCP) status,
and the serial port baud rate and type.

NOTE: None of the settings can be changed from this menu; to make adjustments, use

the Edit Comm Settings menu (see “

Edit Comm Settings Menu

”).

The flow diagram below shows the screens and the settings that can be viewed from this
menu.

View Comm

Settings

Serial Port

9600 RS232

MAC Address

0005A605CDC7

DHCP Mode

Off

Next

Next

Next

Advanced

Configuration

Menu

Serial Port

View baud rate and port
protocol.

MAC Address

View Media Access Code
(MAC) hardware address.

IP Address

192.168.254.254

Next

Next

IP Address

View unit IP address.

Gateway Address
000.000.000.000

Gateway Address

View gateway IP address.

DHCP Mode

View Dynamic Host
Configuration Protocol
(DHCP) On/Off status.

Subnet Mask

255.255.000.000

Subnet Mask

View subnet mask IP address.

Next

Next

Figure 20.

View Comm Settings Menu

Edit Comm Settings Menu

This menu lets you make changes to the serial port configuration, IP addresses, and the
DHCP mode. Although the Edit Comm Settings menu has almost all the same screens as the
View Comm Settings menu, it is accessed differently.

NOTE: You can access the Edit Comm Settings menu from any other menu or from the

default cycle.

To display the Edit Comm Settings menu:

1.

Press and hold the Next button.

2.

While holding the Next button, press the Detail and Color/Tint buttons simultaneously.

3.

Hold all three buttons until the Edit Comm Settings screen is displayed (approximately
2 seconds).

If no activity occurs within 30 seconds, the DVS saves all settings and returns to the default
cycle.