beautypg.com

Set current, Connection port timeout – Extron Electronics DVS 510 Series User Guide User Manual

Page 77

background image

DVS 510 Series • Remote Configuration and Control

71

Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Ethernet Data Port
Set current connection port
timeout

E

0 *

X12(

TC

}

Pti0 *

X12(

]

Set number of seconds (in tens
of seconds) before timeout on IP
connections.

X12(

= 1 through 65000.

View current connection port
timeout

E

0 TC

}

X12(

]

Set global port timeout

E

1*

X12(

TC

}

Pti1*

X12(

]

View global port timeout

E

1TC

}

X12(

]

IP Setup Commands
Set unit name

E

X8@

CN

}

Ipn •

X8@

]

Set DVS unit name

X8@

.

X8@

can be up to 24 characters
consisting of A to Z, a to z,

0 through 9, and hyphen (-).
The first letter must be
alphabetical; the last one must
not be a hyphen.

View unit name

E

CN

}

X8@

]

Reset unit name to factory
default

24

E

• CN

}

Ipn •

X11%

]

Reset DVS name to its factory
default name

X11%

.

X11%

consists of the model name

and the last three pairs of the
MAC address.

Example:

E

•CN

}

Ipn•DVS-510-SA-05-62-3D

]

Set time and date

24

E

X8#

CT

}

Ipt

X8#

]

X8#

is the local date and time

format. The set format is
MM/DD/YY-HH:MM:SS. (The
hours, minutes, and seconds can
also be separated by periods.)
Examples:

11/13/06-10:54:00 or

11/13/06-10.54.00

View time and date

E

CT

}

X8#

]

Set GMT offset

24

E

X7#

CZ

}

Ipz

X7#

]

Set the Greenwich Mean Time
(GMT) offset value (

X7#

) for

the DVS location. GMT offset
(-12.00 to +14.00) represents
the time difference in hours
and minutes (± hh:mm relative
to Greenwich, England). The
plus sign and leading zero are
optional.

X7#

is in the format hh:mm.

Example:

5:30 or 5.30 = +05:30

NOTE: In the command, the divider between hours and minutes can be a colon or a period. In the response, it is a colon.

Example:

E

8.0CZ

}

Ipz+08:00

]

View GMT offset

E

CZ

}

X7#

]