Command and Response Table for IP-Specific SIS Commands

Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Bidirectional Serial Port
Send data string

E

X7!

*

X8&

*

X8*

*

X9!

RS

}

X7@

response from command

]

Configure port type

E

X!

*

X7!

CY

}

Cpn

X!

• Cty

X7!

]

For

X7!

: 0 = RS-232; 1 = RS-422

Configure port parameters

24

E

X7!

*

X9%

,

X9^

,

X9&

,

X9*

CP

}

Cpn

X7!

X9%

,

X9^

,

X9&

,

X9*

]

Set baud rate

X9%

, parity

X9^

,

X9&

data bits, and

X9*

stop bits

for port

X7!

.

X9%

= 9600, 19200, 38400, or

115200 (default = 9600)

X9^

= odd, even, none, mark,

or space. (Only the first letter is
required.)

X9&

= Data bits: 7 or 8

(default = 8)

X9*

= Stop bits: 1 or 2

(default = 1)

View port parameters

E

X7!

CP

}

X9%

,

X9^

,

X9&

,

X9*

]

Configure flow control

24

E

X7!

*

X10)

,

X10!

CF

}

Cpn

X7!

• Cfl

X10)

,

X10!

]

Set flow control type

X10)

for

port

X7!

with

X10!

ms between

bytes. For

X10)

:

H = Hardware

S = Software

N = None (default)

X10!

= 0000 through 0001

(default = 0 ms)

View flow control

E

X7!

* CF

}

X10)

,

X10!

]

Configure receive timeout

24

E X7!

*

X8&

*

X8*

*

X9#

*

X9!

CE

}

Cpn

X7!

• Cce

X8&

,

X8*

,

X9#

,

X9!

CE

]

NOTES:

X8&

= Time in tens of milliseconds that the DVS will wait for receipt of the first response character before

terminating the command. (Default = 1 = 10 ms; max. = 32767.)

X8*

= Time in tens of milliseconds that the DVS will wait between characters being received via a serial port before

terminating the current command or receive operation. (Default = 2 = 20 ms; max. = 32767.)

X9!

= #L or #D. The letter parameter is case sensitive (requires capital D or capital L). For

X9!

:

L = Length of the message to be received,
D = Delimiter value. A delimiter of ASCII 0A = 10D.
# = Byte count (for L) or a single ASCII character expressed in decimal form (for D). Byte count # can be
0 through 32767; default = 0. The ASCII decimal # can be 0 through 00255; default = the byte count.
A 3-byte length = 3L. The response includes leading zeros.

X9#

= Priority Status for port

X7!

receiving timeouts. For

X9#

:

0 = Use Send data string command parameters (default);
1 = Use Configure receive timeout command parameters. The response includes leading zeros.

View receive timeout

E

X7!

CE

}

X8&

,

X8*

,

X9#

,

X9!

]