beautypg.com

Front panel lockout (executive mode), Additional features, Freeze – Extron Electronics DVS 510 Series User Guide User Manual

Page 48: Power save modes, Freeze power save modes, Front panel lockout (executive modes)

background image

DVS 510 Series • Operation

42

Front Panel Lockout (Executive Mode)

To prevent accidental changes to settings, you can lock the DVS 510 front panel controls by
placing the scaler in lock (executive) mode 1 or 2. While the DVS is in lock mode, RS-232,
RS-422, and Ethernet communication, as well as IR remote control, remain available.

Lock mode 1 locks all front panel functions. This mode can be enabled or disabled
only by SIS commands (see the

Front Panel Security Lockout (Executive Mode)

commands on page 64 in the Command and Response Table for SIS Commands).

Lock mode 2 locks all front panel functions except input selection, PIP, volume
control, and Auto-Image. To enable lock mode 2, press and hold the Position and Size
buttons simultaneously until

Executive

Mode

2

Enabled

appears in the LCD window

(approximately 2 seconds).
To exit lock mode 2, press and hold the Position and Size buttons again until

Executive

Mode

Disabled

appears in the LCD window (approximately 2 seconds).

NOTE: The IR receiver can be locked (default state) and unlocked via SIS commands (see

the

IR Receiver

commands on page 65 in the Command and Response Table for

SIS Commands).

Additional Features

The following features are available via one or more of the following: SIS commands, the
Signal Processing Products Control Program, the DVS 510 HTML pages, or IR remote control.
They cannot be accessed via the front panel.

Freeze

This function freezes the current image on the display. You can freeze and unfreeze the
image using the Windows-based control software (see the SPPCP help file), SIS commands
via an RS-232 or RS-422 connection (see the

Freeze

commands on page 63 in the

Command and Response Table for SIS Commands) or the web pages (see “

User Control

Page

” on page 99).

If you switch inputs while the image is frozen, the freeze mode is cancelled and the image
from the new input is displayed.

Power Save Modes

When there is no active video for the current input, you can disable the output sync so that
a display can go into a lower power or standby state. This can increase the life of the display
panel or projector lamp. You can select the power save mode using SIS commands (see the

Power Save/Screen Saver

commands on page 60 in the Command and Response Table for

SIS Commands) or the Signal Processing Products Control Program (see the SPPCP help file).
The power save options are:

Mute video to black, retaining output sync.

Display a blue screen.

Display a blue screen for 1 minute, then mute all sync outputs.