Extron Electronics DVS 510 Series User Guide User Manual
Page 82

DVS 510 Series • Remote Configuration and Control
76
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Stream Files via Telnet, RS-232, or RS-422
Load file to user flash
memory
24,28
E
+UF filesize, filename
}
Upl
]
Load file to user flash and set
specific time and date
24,28
E
+UF filesize*day-of-week
•
month
•
day
•
year
•
hour
•
minute
•
second
,
filename
}
Upl
]
Day-of-week = 1–7
(1 = Sunday, 2 = Monday ...)
Month = 1–12
(1 = Jan, 2 = Feb, ...)
Day = 1–31
Hour = 0–23
Minute and Second = 0–59
NOTES: If there is insufficient space on the unit to store the sent file, the response is Fld
]
instead of Upl
]
to denote
failure.
You can use this command to update firmware by loading a firmware file with a .S19 extension. If the unit
determines that the .s19 file is not intended for the DVS, the Upl
]
response is followed by Fwm
]
(firmware
mismatch).
Retrieve file from user flash
memory
24,28
E
filename SF
}
Responds with 4 bytes of file-size plus raw, unprocessed
data in the file.
Stream files via Port 80
Load file to user flash memory
Use a POST on port 80, followed by the delimited data to be written to the flash file
memory.
Retrieve file from user flash
memory
Send a page GET on port 80 followed by:
Ie.http://192.168.254.254/mypage.html?cmd=WSF|
Responds with raw, unprocessed data in file.
Back Up and Restore Unit Configuration
Save unit configuration (to file
system)
E
1 * configuration type XF
}
Cfg1 * configuration type
]
For configuration type:
0 = IP configuration (ip.cfg)
1 = Event configuration
(event.cfg)
2 = Unit-specific parameters
(box.cfg)
The files are stored in the
directory /nortxe-backup
created on the unit by the Save
commands.
Restore unit configuration
E
0 * configuration type XF
}
Cfg0 * configuration type
]