Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Stream Files via Telnet, RS-232, or RS-422
Load file to user flash
memory

24,28

E

+UF filesize, filename

}

Upl

]

Load file to user flash and set
specific time and date

24,28

E

+UF filesize*day-of-week

month

day

year

hour

minute

second

,

filename

}

Upl

]

Day-of-week = 1–7
(1 = Sunday, 2 = Monday ...)
Month = 1–12
(1 = Jan, 2 = Feb, ...)
Day = 1–31
Hour = 0–23
Minute and Second = 0–59

NOTES: If there is insufficient space on the unit to store the sent file, the response is Fld

]

instead of Upl

]

to denote

failure.

You can use this command to update firmware by loading a firmware file with a .S19 extension. If the unit
determines that the .s19 file is not intended for the DVS, the Upl

]

response is followed by Fwm

]

(firmware

mismatch).

Retrieve file from user flash
memory

24,28

E

filename SF

}

Responds with 4 bytes of file-size plus raw, unprocessed
data in the file.

Stream files via Port 80
Load file to user flash memory

Use a POST on port 80, followed by the delimited data to be written to the flash file
memory.

Retrieve file from user flash
memory

Send a page GET on port 80 followed by:
Ie.http://192.168.254.254/mypage.html?cmd=WSF|

Responds with raw, unprocessed data in file.

Back Up and Restore Unit Configuration
Save unit configuration (to file
system)

E

1 * configuration type XF

}

Cfg1 * configuration type

]

For configuration type:
0 = IP configuration (ip.cfg)

1 = Event configuration
(event.cfg)

2 = Unit-specific parameters
(box.cfg)
The files are stored in the
directory /nortxe-backup
created on the unit by the Save
commands.

Restore unit configuration

E

0 * configuration type XF

}

Cfg0 * configuration type

]