DVS 510 Series • Remote Configuration and Control

48

IP Address

To access the DVS 510 or DVS 510 SA via the Ethernet port, obtain the IP address of the
scaler from your network administrator. If the IP address has been changed to an address
comprised of words and characters, you can determine the actual numeric IP address using
the ping (ICMP) utility (see “

IP Addressing

” on page 116 for more details). If the IP address

has not been changed, the factory-specified default is 192.168.254.254.

Establishing an Ethernet Connection Using TCP

Establish a network connection to a DVS as follows:

1.

Open a TCP connection to port 23, using the IP address of the scaler.
The scaler responds with a copyright message that includes the date, the name of
the product, firmware version, part number, and the current date and time (see

Scaler-initiated Messages

” on the next page).

NOTE: If the scaler is not password-protected, the device is ready to accept SIS

commands immediately after it sends the copyright message.

If the scaler is password-protected, a

password

prompt appears below the

copyright message.

2.

If the scaler is password protected, enter the appropriate administrator or user
password.

3.

If the password is accepted, the scaler responds with

Login

User

or

Login

Administrator

.

4.

If the password is not accepted, the

Password

prompt reappears.

Connection Timeouts

The Ethernet link times out after a designated period of no communications. By default,
this timeout value is set to 5 minutes, but the value can be changed (see the

Set current

connection port timeout

command on page 71, in the Command and Response Table for

IP-specific SIS Commands).

NOTE: Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (

Q

) command to keep the connection active. If there are long

idle periods, Extron recommends disconnecting and reopening the connection
when another command must be sent.

Using SIS Commands

SIS commands consist of one or more characters per command field. They do not require
any special characters to begin or end the command character sequence. When the DVS
determines that a command is valid, it executes the command and sends a response to the
host device. Each scaler response to an SIS command ends with a carriage return and a line
feed (CR/LF = ]), which signals the end of the response character string. A string is one or
more characters.