Extron Electronics DVS 510 Series User Guide User Manual
Page 65
DVS 510 Series • Remote Configuration and Control
59
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Vertical Size
NOTE: The vertical size range (
X1&
) is based on the current output resolution.
Specific value
E
X1&
VSIZ
}
Vsiz
X!
*
X1&
]
Set the window height to
X1&
.
Increase size
E
+
VSIZ
}
Vsiz
X!
*
X1&
]
Make the window taller.
Decrease size
E
–
VSIZ
}
Vsiz
X!
*
X1&
]
Make the window shorter.
View
E
VSIZ
}
X1&
]
View vertical sizing (height) value
X1&
.
Zoom
Set specific zoom value
E
X1*
ZOOM
}
Zoom
X!
*
X1*
]
Set the zoom percentage to
X1*
.
Zoom in
E
+
ZOOM
}
Zoom
X!
*
X1*
]
Zoom in and make the image larger.
Zoom out
E
–
ZOOM
}
Zoom
X!
*
X1*
]
Zoom out and make the image smaller.
View zoom
E
ZOOM
}
X1*
]
View the zoom percentage.
Pan
NOTE: The pan value (
X1(
) is based on the current zoom setting.
Set horizontal value
E
X1(
HPAN
}
Hpan
X!
*
X1(
]
Set the horizontal pan value to
X1(
.
Right
E
–
HPAN
}
Hpan
X!
*
X1(
]
Set the value to pan to the right.
Left
E
+
HPAN
}
Hpan
X!
*
X1(
]
Set the value to pan to the left.
View horizontal pan
value
E
HPAN
}
X1(
]
View the horizontal pan value.
Set vertical pan value
E
X1(
VPAN
}
Vpan
X!
*
X1(
]
Set the vertical pan value to
X1(
.
Up
E
–
VPAN
}
Vpan
X!
*
X1(
]
Set the value to pan upward.
Down
E
+
VPAN
}
Vpan
X!
*
X1(
]
Set the value to pan downward.
View vertical pan value
E
VPAN
}
X1(
]
View the vertical pan value.
Output Scaler Rate
Set output rate
E
X2!
RATE
}
Rate
X2!
]
Select an output resolution and refresh
rate (see the
for SIS commands on page 52).
View output rate
E
RATE
}
X2!
]
Show the selected output rate.
NOTE: X!
= Input selection
1 through 10
X1&
= Horizontal and vertical size
(Width and height) Values depend on current output rate.
X1*
= Zoom value
100% through 200%
X1(
= Pan value
-100 through +100 (Values depend on the zoom setting.)
Default
=
0.
X2!
= EDID resolution and refresh rate
See the
available
values.