Ogram help file), sis commands (see the, Input presets, Via an rs-232 or rs-422 connection (see the – Extron Electronics DVS 510 Series User Guide User Manual
Page 69: Freeze
DVS 510 Series • Remote Configuration and Control
63
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Presets (continued)
Input Presets
Recall input preset
2
*
X2^
.
2
Rpr
X2^
]
Recall input preset
X2^
.
Save input preset
2
*
X2^
,
2
Spr
X2^
]
Save the parameters of the current input
to preset X2^ (for saved parameters, see
“
” under “Symbol
Definitions for DVS 510 Series SIS
Commands”).
Input Preset Name
Write preset name
E
X2^
,
X1$
NP
}
Nmp
X2^
,
X1$
]
Set name of preset
X2^
to
X1$
. The
command character is a comma. Presets
can have up to 16 characters.
NOTE: The following characters are invalid in input preset names:
~ @ =
`
[] {} <> ’ ‘ “ ” ; (semicolon) : (colon) | / \ ? and space.
View preset name
E
X2^
NP
}
X1$
]
View the name of input preset
X2^
.
NOTE: To clear an input preset name, enter one space character for
X1$
.
Auto Memories
Enable
E
1
AMEM
}
Amem
1
]
Enable auto memories to automatically
recall the previous settings for the
incoming signal (default).
Disable
E
0
AMEM
}
Amem
0
]
Disable auto memories. Input presets
must be manually recalled to configure
the input.
View setting
E
AMEM
}
X1)
]
View the status of auto memories.
Advanced Configuration
Test Pattern
Set test pattern
E
X2)
TEST
}
Test
X2)
]
Select test pattern
X2)
.
View test pattern
E
TEST
}
X2)
]
View the current test pattern.
Freeze
Set freeze
1
F
Frz
1
]
Freeze the selected input.
Set freeze
0
F
Frz
0
]
Unfreeze the selected input.
View
F
X1)
]
Show the freeze status (1= on, 0= off).
RGB Delay Time
Set RGB delay
E
X3&
VDLY
}
Vdly
X3&
]
Set the time the DVS will delay displaying
the new input to
X3&
.
View setting
E
VDLY
}
X3&
]
View the RGB delay setting.
NOTE: X1)
= Auto memories or freeze status
0 = disabled, 1 = enabled
X1$
= Input preset name
Up to 16 characters; no special characters
X2)
= Test pattern
0 through 13 (see “
” under “Symbol Definitions for
DVS 510 Series SIS Commands” for the available test patterns).
X2^
= Input preset number
1 through 128
X3&
= RGB delay amount
0 through 50 in 0.1-second increments. Default is 05 (0.5 seconds).