DVS 510 Series • Remote Configuration and Control

63

Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Presets (continued)

Input Presets

Recall input preset

2

*

X2^

.

2

Rpr

X2^

]

Recall input preset

X2^

.

Save input preset

2

*

X2^

,

2

Spr

X2^

]

Save the parameters of the current input
to preset X2^ (for saved parameters, see

Input presets

” under “Symbol

Definitions for DVS 510 Series SIS
Commands”).

Input Preset Name

Write preset name

E

X2^

,

X1$

NP

}

Nmp

X2^

,

X1$

]

Set name of preset

X2^

to

X1$

. The

command character is a comma. Presets
can have up to 16 characters.

NOTE: The following characters are invalid in input preset names:

~ @ =

`

[] {} <> ’ ‘ “ ” ; (semicolon) : (colon) | / \ ? and space.

View preset name

E

X2^

NP

}

X1$

]

View the name of input preset

X2^

.

NOTE: To clear an input preset name, enter one space character for

X1$

.

Auto Memories

Enable

E

1

AMEM

}

Amem

1

]

Enable auto memories to automatically
recall the previous settings for the
incoming signal (default).

Disable

E

0

AMEM

}

Amem

0

]

Disable auto memories. Input presets
must be manually recalled to configure
the input.

View setting

E

AMEM

}

X1)

]

View the status of auto memories.

Advanced Configuration

Test Pattern

Set test pattern

E

X2)

TEST

}

Test

X2)

]

Select test pattern

X2)

.

View test pattern

E

TEST

}

X2)

]

View the current test pattern.

Freeze

Set freeze

1

F

Frz

1

]

Freeze the selected input.

Set freeze

0

F

Frz

0

]

Unfreeze the selected input.

View

F

X1)

]

Show the freeze status (1= on, 0= off).

RGB Delay Time

Set RGB delay

E

X3&

VDLY

}

Vdly

X3&

]

Set the time the DVS will delay displaying
the new input to

X3&

.

View setting

E

VDLY

}

X3&

]

View the RGB delay setting.

NOTE: X1)

= Auto memories or freeze status

0 = disabled, 1 = enabled

X1$

= Input preset name

Up to 16 characters; no special characters

X2)

= Test pattern

0 through 13 (see “

Test pattern

” under “Symbol Definitions for

DVS 510 Series SIS Commands” for the available test patterns).

X2^

= Input preset number

1 through 128

X3&

= RGB delay amount

0 through 50 in 0.1-second increments. Default is 05 (0.5 seconds).