beautypg.com

Extron Electronics DVS 510 Series User Guide User Manual

Page 60

background image

DVS 510 Series • Remote Configuration and Control

54

X4%

= Video switching effect

0 = Cut: instantly switches video.

1 = Fade: video fades to black, then fades to the new

input.

X5)

= Audio volume

Range of 0 through 100

X5!

= Audio output format

1 = Mono

2 = Stereo (default)

X5@

= Audio gain level

0 through 12 dB (decibels above zero)

X5#

= Audio attenuation level

12 through 0 dB (decibels below zero)

X5$

= Audio gain or attenuation level

Unit response; can be positive or negative.

X5%

= Audio treble and bass

Range = 0 through 16 in 1.5 dB increments

(-12 dB through +12 dB)

0 = -12 dB

8 = 0 dB (default)

16 = +12 dB

X5&

= PIP Audio source

0 = Follow main window (default).

1 = Follow PIP window.

X5*

= Digital audio input type

2 = Digital, 2-channel LPCM 48 kHz (default)

3 = Digital, full audio (7.1, DTS, and so on)

X5(

= Front panel security lock

0 = Disabled: full front panel access (default)

(executive mode)

1 = Lock mode 1: all front panel functions locked

2 = Lock mode 2: limited front panel access (input

selection, PIP, volume control, and Auto-Image)