X4%
= Video switching effect
0 = Cut: instantly switches video.
1 = Fade: video fades to black, then fades to the new
input.
X5)
= Audio volume
Range of 0 through 100
X5!
= Audio output format
1 = Mono
2 = Stereo (default)
X5@
= Audio gain level
0 through 12 dB (decibels above zero)
X5#
= Audio attenuation level
12 through 0 dB (decibels below zero)
X5$
= Audio gain or attenuation level
Unit response; can be positive or negative.
X5%
= Audio treble and bass
Range = 0 through 16 in 1.5 dB increments
(-12 dB through +12 dB)
0 = -12 dB
8 = 0 dB (default)
16 = +12 dB
X5&
= PIP Audio source
0 = Follow main window (default).
1 = Follow PIP window.
X5*
= Digital audio input type
2 = Digital, 2-channel LPCM 48 kHz (default)
3 = Digital, full audio (7.1, DTS, and so on)
X5(
= Front panel security lock
0 = Disabled: full front panel access (default)
(executive mode)
1 = Lock mode 1: all front panel functions locked
2 = Lock mode 2: limited front panel access (input
selection, PIP, volume control, and Auto-Image)