Extron Electronics DVS 510 Series User Guide User Manual
Page 80
DVS 510 Series • Remote Configuration and Control
74
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Password and Security Settings (continued)
Set user password
14
E
X10@
CU
}
Ipu •
X10(
]
Set user access password
X10@
.
X10@
= 4 to 12 alphanumeric
characters. The password is case
sensitive. Special characters
(spaces or symbols) are not
allowed.
X10(
= password. If a password
exists, the unit responds with
the password (RS-232 or RS-422
connection) or 4 asterisks
(****) (IP connection). If there
is no password, the response is
empty.
NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the
DVS has not been configured yields an E14 error response from the scaler. If the administrator password is cleared
(removed), the user password is removed also.
View user password
E
CU
}
X10(
]
Reset (clear) user password
E
• CU
}
Ipu •
]
Clear or remove the user
password.
Query session security level
E
CK
}
X11*
]
In verbose mode:
Pvl
X11*
]
Remap Port Destinations
Set Telnet port map
24
E
X7@
MT
}
Pmt
X7@
]
X7@
= Telnet port number
Reset Telnet port map
24
E
23MT
}
Pmt00032
]
Disable Telnet port
E
0MT
}
Pmt00000
]
View Telnet port mapping
E
MT
}
X7@
]
NOTES:
•
Duplicate port number assignments are not permitted (for example, the Telnet and web mapping cannot be the
same). An E13 (invalid parameter) error code results.
•
Remapping of the port number other than to reset it to defaults 80 or 23 or to disable it by resetting it to 0 can
be done only to ports numbered 1024 or higher.
Set web port map
24
E
X7@
MH
}
Pmh
X7@
]
Reset web port map
24
E
80MH
}
Pmh00080
]
Disable web port
24
E
0MH
}
Pmh00000
]
View web port map
24
E
MH
}
X7@
]
Set Direct Access port map
24
E
X7@
MD
}
Pmd
X7@
]
Reset Direct Access port map
24
E
2001MD
}
PMD02001
]
Disable Direct Access port map
24
E
0MD
}
PMD00000
]
View Direct Access port map
24
E
MD
}
X7@
]