beautypg.com

Ou can also enable pip via sis commands (see the, Picture-in-picture [pip, Commands – Extron Electronics DVS 510 Series User Guide User Manual

Page 66: Power save/screen saver

background image

DVS 510 Series • Remote Configuration and Control

60

Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Output Sync Format and Polarity
Set sync format

E

X2$

OSYN

}

Osyn

X2$

]

Set the sync format for the VGA output
to

X2$

.

NOTE: Setting the sync format to YUV bi-level and tri-level also affects the colorspace of the DVI output.

View sync format

E

OSYN

}

X2$

]

View the current output sync format.

Set polarity

E

X2#

OPOL

}

Opol

X2#

]

Set the sync polarity for the VGA output
to

X2#

.

View polarity

E

OPOL

}

X2#

]

View the output video and sync polarity.

Power Save / Screen Saver

NOTE:

The action initiated by these commands takes place when there is no active video on the selected input.

Video mute

E

0

PSAV

}

Psav

0

]

Mute the video output and retain the
output sync (default). The screen is black.

Blue output

E

1

PSAV

}

Psav

1

]

Set the video output to blue.

Blue output and
timeout

E

2

PSAV

}

Psav

2

]

Set the video output to blue for 1 minute,
then mute the output video and sync.

View setting

E

PSAV

}

X4)

]

View the current power save mode.

Picture-in-Picture (PIP)
PIP on

E

X!

PIP

}

Pip

X!

]

Enable picture-in-picture with input

X!

as

the PIP input.

NOTES:

When PIP is enabled, all picture control commands apply only to the image in the PIP window.

If input

X!

is in the same high or low resolution category as the currently displayed input, the error code E13

(invalid parameter) is returned. The table below shows the categories for each input.

Input High Resolution

Low Resolution

1

Composite

2

Composite

3

S-video

4

S-video

5

RGB, YUVp/HDTV

YUVi, RGBcvS

6

RGB, YUVp/HDTV

YUVi, RGBcvS

7

RGB, YUVp/HDTV

YUVi, RGBcvS

8

DVI (all formats)

9

RGB, YUVp/HDTV

YUVi, RGBcvS

10

DVI (all formats)

PIP off

E

0

PIP

}

Pip

0

]

Disable PIP.

NOTE: X!

= Input selection for PIP

1 through 10

X2#

= Output polarity

0 = H-/V- (default), 1 = H-/V+, 2 = H+/V-, 3 = H+/V+

X2$

= Output sync format

0 = RGBHV (default), 1 = RGBS, 2 = RGsB, 3 = YUV bi-level,

4 = YUV tri-level

X4)

= Power save and screen saver modes

0 = Black screen; output sync retained

1 = Blue screen; continuous sync

2 = Timed blue screen. Screen is blue for 1 minute, then output video

and sync are muted.