beautypg.com

Rainbow Electronics DS3131 User Manual

Page 55

background image

DS3131

55 of 174

Register Name:

BERTC1

Register Description:

BERT Control Register 1

Register Address:

0504h

Bit #

7

6

5

4

3

2

1

0

Name

EIB2 EIB1 EIB0 SBE reserved

reserved

reserved TC

Default 0 0

0 0

0

0

0

0

Bit #

15

14

13

12

11

10

9

8

Name

Alternating Word Count

Default

0 0 0 0 0 0 0 0

Note:

Bits that are underlined are read-only; all other bits are read-write.


Bit 0/Transmit Pattern Load (TC).
A low-to-high transition loads the pattern generator with repetitive or
pseudorandom pattern that is to be generated. This bit should be toggled from low to high whenever the host
wishes to load a new pattern. Must be cleared and set again for subsequent loads.

Bit 4/Single Bit-Error Insert (SBE).
A low-to-high transition creates a single bit error. Must be cleared and set
again for a subsequent bit error to be inserted.

Bit 5/Error Insert Bit 0 (EIB0); Bit 6/Error Insert Bit 1 (EIB1); Bit 7/Error Insert Bit 2 (EIB2).
Automatically inserts bit errors at the prescribed rate into the generated data pattern. Useful for verifying error
detection operation.

EIB2 EIB1 EIB0

Error

Rate

Inserted

0 0 0

No

errors

automatically

inserted

0 0 1

10E-1

0 1 0

10E-2

0 1 1

10E-3

1 0 0

10E-4

1 0 1

10E-5

1 1 0

10E-6

1 1 1

10E-7

Bits 8 to 15/Alternating Word Count Rate. When the BERT is programmed in the alternating word mode, the
words repeat for the count loaded into this register, then flip to the other word and again repeat for the number of
times loaded into this register. The valid count range is from 05h to FFh.