ZyWALL 10~100 Series Internet Security Gateway

Troubleshooting

A

Appendix A

Troubleshooting

This chapter covers potential problems and possible remedies. After each problem description,

some instructions are provided to help you to diagnose and to solve the problem. Please see our

included disk for further information. DMZ applies to the ZyWALL 100.

Problems Starting Up the ZyWALL

Chart 1 Troubleshooting the Start-Up of Your ZyWALL

PROBLEM CORRECTIVE

ACTION

Make sure that you have the included power adaptor or cord connected to the ZyWALL
and to an appropriate power source.

Replace the fuse if it is burnt out (see the appendices for more on changing a fuse).

None of the
LEDs turn on
when you
turn on the
ZyWALL.

If the error persists, you may have a hardware problem. In this case, you should contact
your vendor.

1. Check to see if the ZyWALL is connected to your computer’s console port.

VT100 terminal emulation

9600 bps is the default speed on leaving the factory. Try
other speeds in case the speed has been changed.

Cannot
access the
ZyWALL via
the console
port.

2. Check to see if the
communications program is
configured correctly. The
communications software
should be configured as
follows:

No parity, 8 data bits, 1 stop bit, data flow set to none.