Intel386™ EX EMBEDDED MICROPROCESSOR USER’S MANUAL
D-66
Timer
n (Status Format)
TMR
n (n = 0–2)
Expanded Addr:
ISA Addr:
Reset State:
F040H, F041H
F042H
0040H, 0041H
0042H
XXH
7
0
OUTPUT
NULCNT
RW1
RW0
M2
M1
M0
CNTFMT
Bit
Number
Bit
Mnemonic
Function
7
OUTPUT
Output Status:
This bit indicates the current state of the counter’s output signal.
0 = OUT
n is low
1 = OUT
n is high
6
NULCNT
Count Status:
This bit indicates whether the latest count written to the counter has
been loaded. Some modes require a gate-trigger before the counter
loads new count values.
0 = the latest count written to the counter has been loaded
1 = a count has been written to the counter but has not yet been loaded
5–4
RW1:0
Read/Write Select Status:
These bits indicate the counter’s programmed read/write selection.
00 = Never occurs
01 = read/write least-significant byte only
10 = read/write most-significant byte only
11 = read/write least-significant byte first, then most-significant byte
3–1
M2:0
Mode Status:
These bits indicate the counter’s programmed operating mode.
000 = mode 0
001 = mode 1
X10 = mode 2
X11 = mode 3
100 = mode 4
101 = mode 5
X is a don’t care.
0
CNTFMT
Counter Format Status:
This bit indicates the counter’s programmed count format.
0 = binary (16 bits)
1 = binary coded decimal (4 decades)