beautypg.com

Close, Copymem – Freescale Semiconductor Microcontrollers User Manual

Page 766

background image

Debugger Engine Commands

Debugger Commands

766

Microcontrollers Debugger Manual

CLOSE

The CLOSE command is used to close a component.

Component names are: Assembly, Command, Coverage, Data, Inspect, IO_Led, Led,
Memory, Module, Phone, Procedure, Profiler, Recorder, Register, SoftTrace, Source,
Stimulation.

Usage

CLOSE component | *

where * means “all components”.

Components

Debugger engine.

Example:

in>CLOSE Memory

The Memory component window is closed (unloaded).

COPYMEM

The COPYMEM command is used to copy a memory range to a destination range
defined by the beginning address. This command works on defined memory only. The
source range and destination range are tested to ensure they are not overlayed.

Usage

COPYMEM dest-address

Components

Memory.

Example:

in>copymem 0x3FC2A0..0x3FC2B0 0x3FC300

The memory from 0x3FC2A0 to 0X3FC2B0 is copied to the memory at 0x3FC300
to 0x3FC310. This Memory range appears in red in the Memory Component.