HCS08 On-Chip DBG Module

Context Menu Entries in Source, Data, Assembly and Memory Windows

509

Microcontrollers Debugger Manual

Figure 23.6 Controlpoints Configuration Window - Markpoints Tab

Editing triggers through the Markpoints tab in the Controlpoints Configuration
window below is not user friendly. However, the Save and Restore on load option (also
available with breakpoints and watchpoints) can be very useful to automatically save the
application with the DBG module setup and trigger positions saved as they are set in the
current application.

Data and Memory Windows

Data and Memory windows have context menu options to set/delete

Memory Access

Triggers

A and/or B, a

Trigger Settings

option to set the DBG module triggers settings and

the

Trigger Module Usage

option to globally set the DBG module functionality.

Setting a trigger, which can be assimilated as a complex breakpoint or watchpoint, is as
simple as setting a watchpoint.