Plus i/o, Analog in, Digital in – SMA Sunny Boy Control User Manual
Page 99: Digital out, Variable, Monitoring

Sunny Boy Control
SMA Technologie AG
User Manual
SUNBC-14:NE0206
95
Hardware-Based Configuration
To configure the connectors on the Sunny Boy Control Plus itself, use the menu
“Setup…Interfaces”.
[ Plus I/O ]
„Analog In
Analog inputs AIN1–AIN8
„Digital In
Digital inputs DIN1–DIN8
Section 7.3.2
„Digital Out
Digital outputs DOUT1–DOUT8
Section 7.3.3
„Variable
Variables Var1–Var16
„Monitoring
Monitoring channels Mon1–Mon8
Fig. 7.2: Configuring the analog and digital interfaces
When leaving the “Plus I/O” menu, the changes made are saved after confirma-
tion. When the analog, digital, variable, or monitoring channels are changed, the
device generates a new channel description, which can be recognized by a change
of the device model information (e.g., from “SBC+a4Eb” to “SBC+a4Ec”).
Software-Based Configuration
The Sunny Boy Control Plus can also be configured using the Sunny Data Control
software.
Parameter
Channel
Value
Description
+a_SET Choice
--- Selecting
the
channel to be changed
+b_SET Help
Select with...
Help messages for different input options
+c_SET Value
---
Displaying the current setting for the se-
lected channel
+d_SET Plus-Function
---
“store”, “undo”, “Profile 1–2”
Table 7.1: Configuration using Sunny Data Control