Plus i/o, Analog in, Digital in – SMA Sunny Boy Control User Manual

Page 99: Digital out, Variable, Monitoring

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC-14:NE0206

95

Hardware-Based Configuration

To configure the connectors on the Sunny Boy Control Plus itself, use the menu
“Setup…Interfaces”.

[ Plus I/O ]

„Analog In

Analog inputs AIN1–AIN8

Section 7.2

„Digital In

Digital inputs DIN1–DIN8

Section 7.3.2

„Digital Out

Digital outputs DOUT1–DOUT8

Section 7.3.3

„Variable

Variables Var1–Var16

Section 7.4

„Monitoring

Monitoring channels Mon1–Mon8

Section 7.5

Fig. 7.2: Configuring the analog and digital interfaces

When leaving the “Plus I/O” menu, the changes made are saved after confirma-
tion. When the analog, digital, variable, or monitoring channels are changed, the
device generates a new channel description, which can be recognized by a change
of the device model information (e.g., from “SBC+a4Eb” to “SBC+a4Ec”).

Software-Based Configuration

The Sunny Boy Control Plus can also be configured using the Sunny Data Control
software.

Parameter

Channel

Value

Description

+a_SET Choice

--- Selecting

the

channel to be changed

+b_SET Help

Select with...

Help messages for different input options

+c_SET Value

---

Displaying the current setting for the se-
lected channel

+d_SET Plus-Function

---

“store”, “undo”, “Profile 1–2”

Table 7.1: Configuration using Sunny Data Control