external sensor is available, the current system power (Pac) can be defined as the
starting condition (e.g., 200 W < Pac < 1500 W).

Software-Based Configuration

Parameter

Channel

Value

+a_SET Choice

Monitor START

+b_SET Help

Fct (-, a), Name, Valid: min, max, Error: Low, High

+c_SET Value

a, +Gi, 200, 1300, 0, 1500

Table 7.17: Configuring the monitor starting condition

Setting Explanation

Fct

Function of the variable

Abbrev. ..... Explanation

-................deactivated

a...............activated

ChName

Name of the channel to be monitored

Vaild min, max

Definition of the valid monitoring range (lower & upper end)

Error Low, High

Lower & upper limits for generating an error

Table 7.18: Configuring the monitor starting condition