Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC

-

14

:

NE0206

150

The combination of the number of measuring channels and measuring intervals results
in the following storage capacities.

Measuring channel storage capacity

Chan-

nels

Cycles Spot

values

2

Measuring interval

1–5 inv. 50 inv. 5 min. 10 min. 15 min. 30 min. 60 min. 120 min

.

Hours

(approx.)

Days

1

19255 27 321 134 267 401 802 1605

3209

2

15906 22 265 110 221 331 663 1326

2651

3

13550

19 226 94 188 282 565

1129

2258

4

11801

16 197 82 165 246 492 983

1967

5

10453

15 174 73 145 218 436 871

1742

10

6652 9 111 46 92 139 277 554

1109

15

4878 7 81 34 68 102

203

406

813

20

3851 5 64 27 53 80 160

321

642

25

3181 4 53 22 44 66 133

265

530

50

1702 2 28 12 24 35 71 142

284

100

882 1,2 15 6 12 18 37 73 147

150

595 0,8 10 4 8 12 25 50 99

200

449

0,6 7 3 6 9 19

37

75

250

360

0,5 6 3 5 8 15

30

60

Table 10.2: Storage depth in hours and days

Changing channels reduces the current storage capacity by approximately 0.5 % per
configuration change.

If a Sunny Boy Control manages 50 devices, the preset settings (3 channels per de-
vice, 15-minute measuring interval) result in a storage depth of about 12 days.

2

Saving time for 1–5 inverters: 5 seconds

Saving time for 50 inverters: 60 seconds