Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC-14:NE0206

112

Software-Based Configuration

Parameter

Channel

Value

+a_SET Choice

Digital OUT-2

+b_SET Help

Fct (-, sw), Name, LowText, HighText

+c_SET Value

-, +DOUT-2

Table 7.12: Digital output channel configuration

Setting Explanation

Fct

Function of the digital output channel

Abbrev. ..... Explanation

-................deactivated

sw.............Switch

Name

Name of the channel to be displayed

LowText

Text displayed with the “switched off” condition

HighText

Text displayed with the “switched on” condition

Table 7.13: Digital output channel settings

7.4 Variables (VAR-1–VAR-16)

Sixteen variables are available to perform customized calculations. By combining
any of the measured values according to specific requirements, the user can generate
new data. With a variable, analog Vac and Iac measurements, for example, can
produce Pac data.

The variables are calculated in the order VAR-1–VAR-16. This can be important to
know when the formula for one variable contains another variable. For example:
VAR-1 calculates Pac, and VAR-2 determines Eac based on VAR-1. The settings for
the variables can be made in the menu “Setup…Plus I/O…Variables”