Additional Information for Installation

SMA DC-Disconnect
Accessories for PV Inverters

Version:

1.1

Mat.-Nr.

DB-DC-DISCON

Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version
is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow
the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard
this additional information.

The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter.
The SMA DC-Disconnect is NOT an AC circuit breaker.

This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT re-
place the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed
in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DC-
Disconnect and provides information on the torque of the cable connection.

AC Wiring with SMA DC-Disconnect

The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid.
The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240
V and 277 V grid.

Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy.
This instruction does NOT replace the Sunny Boy Installation Guide.

L1

Connect the black L1 (AC line 1 or UN-
GROUNDED) wire to the terminal la-
beled L1 in the SMA DC-Disconnect

L2

Connect the red L2 (AC line 2) to the ter-
minal labeled L2 in the SMA DC-Discon-
nect.

Only for 277 V:

L2 terminal not used!

N

Connect the white N (AC line N) wire to
the terminal labeled N in the SMA DC-
Disconnect.

PE

Connect the green-yellow AC equip-
ment-ground wire to the PE terminal la-
beled in the SMA DC-Disconnect.