Parameters data explanation ac_... alarm contact, Co_… / ko_... communication, Da_... data archive – SMA Sunny Boy Control User Manual

Page 131: Es_... switching contact

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC

-

14

:

NE0206

127

Parameters Data

Explanation

AC_... Alarm Contact

AC_Default Switch

Contact 1_1

Relay default switch: 1_1, 1_2

AC_Errors

ON

Alarm contact “”ON/OFF” for errors

AC_Speaker deactivated

Beeper signals errors/warnings

AC_Warnings

ON

Alarm contact “”ON/OFF” for warnings

MK_DisplayFlash activated

Display light flashes if error

CO_… / KO_... Communication

CO_Buffer

2 cycles

Number of cycles for buffering the measuring data

CO_CmdRetry

1 times

Number of packet repeats in case of an error

CO_CmdTimeout

4000ms

Max. timespan that the Sunny Boy Control
will wait for an answer from a device

CO_COM1

PowerLine

Type of interface for COM1

CO_COM1 Baud

1200Baud

Rate of transmission to PV system

CO_COM2

RS232

Type of interface for COM2

CO_COM2-Baud 19200Baud

Rate

of transmission to PC

KO_COM1-Prot.

Sunny-Net

Transmission protocol used

KO_COM2-Prot.

Sunny-Net

Transmission protocol used

KO_COM3

RS232

Type of interface for COM3 (Plus only)

KO_COM3-Baud

19200Baud

Rate of transmission for COM3 (Plus only)

KO_COM3-Prot.

Sunny-Net

Transmission protocol used (Plus only)

KO_NET….

Refer to the NET Piggy-Back manual “NETPB-13:EE”

DA_... Data Archive

DA_Data Reading

ON

Data acquisition “ON/OFF”’

DA_Max. Storage

51.42 days

Remaining storage capacity

DA_Meas. Interval

15.00 min

Data-archiving interval

DA_Storage

ON

“ON/OFF” when system is active, “24h” if permanent

E-Mail (refer to the NET Piggy-Back manual “NETPB-13:EE”)

ED_... External Display

ED_InterfacePort deactivated Interface

for external display

ED_TYPE HvG

External

display

model

ES_... Switching Contact

ES_Default Switch

Contact 2_1

Relay default switch: 2_1, 2_2

ES_Minimum Time

60.00 min

Minimum switch-on time of switching contact

ES_Poff 0.00

kW

Switch-off

tolerance of switching contact

ES_Pon 0.00

kW

Switch-on

tolerance of switching contact

ES_Power Switch

deactivated

Switching contact power management activated/deactivated