Interfaces, Communication, 1 communication – SMA Sunny Boy Control User Manual

Page 75: N 6.3, 3 interfaces [ interfaces, Ext. display, Relais out, Com1:sunny boy, Com2:pc, Medium

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC-14:NE0206

71

6.3 Interfaces

[ INTERFACES ]

„Communication

Section 6.3.1

„Ext. Display

Section 6.3.2

„Relais Out

Section 6.3.3

Fig. 6.9: “Interfaces” menu

6.3.1 Communication

The installed interfaces are automatically detected and can be checked under
“COM1:Sunny Boy” (“SUNNY BOY” connector) and “COM2:PC” (“PC COM2”
connector).

[COMMUNICATION ]

„COM1:Sunny Boy

„COM2:PC

Fig. 6.10: Interface options

Powerline communication with the inverters via the COM1 port is limited to 1,200
baud. With an RS232 connection via the COM2 port, the baud rate can be manu-
ally adjusted to as much as 19,200 baud.

[COM1:Sunny Boy]

‡Medium…

…PowerLine

Baudrate… Š

…………1200Baud

Protocol…

…Sunny-Net

Fig. 6.11: COM1/Sunny Boy interface screen