beautypg.com

SMA Sunny Boy Control User Manual

Page 123

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC-14:NE0206

119

Software-Based Configuration

Parameter

Channel

Value

+a_SET Choice

Variable VAR-1

+b_SET Help

Fct (-, a, d), Name, Warning: Low, High, Error: Low, High

+c_SET Value

a, +PR, 80, 95, 70, 100

Table 7.19: Configuration of variables

Setting Explanation

Fct

Function of the variable

Abbrev. ..... Explanation

-................deactivated

a...............activated

d...............daily

Name

Name of the channel to be monitored

Warning Low, High Lower & upper limits for generating a warning

Error Low, High

Lower & upper limits for generating an error

Table 7.20: Configuration of variables