User and installer passwords, Timing, 1 user and installer passwords – SMA Sunny Boy Control User Manual
Page 70: N 6.2.1
Sunny Boy Control
SMA Technologie AG
User Manual
SUNBC-14:NE0206
66
Description of the settings
The “Stand-By Mode” can be activated and deactivated.
The “Gatewaymode” function of the Sunny Boy Control can be set as follows:
•
Proxy
: Inquiries from Sunny Data Control are answered directly. No
packets are forwarded to the connected devices.
•
transparent
: Data acquisition by the Sunny Boy Control is stopped.
Packets from the PC are always forwarded directly to the connected de-
vices.
The “Memory Function” of the Sunny Boy Control allows you to:
•
save parameter settings (“save parameter”)
•
reset parameters to their factory defaults (“Default Param.”)
•
reset measuring channels to their factory defaults (“Default MesCh”)
•
reset “Online-Info“ to its factory defaults (“Default O.Info”)
With the installer function “Service Funct.“ of the Sunny Boy Control, you can:
•
delete archived measuring data (“del Meas.Data”)
•
delete archived daily energy yield data (“del Daily Val.”)
•
remove channel information from the devices (“del Chan.Infos”)
•
reset error counters and operating data (“reset op.data”)
•
reset the error counters only (“reset errors”)
•
reset the device to its factory condition (“reset system”)
6.2.1 User and Installer Passwords
With the function ”User password” of the Sunny Boy Control, you can set the user
password.
With the function “Inst password” of the Sunny Boy Control, you can set the in-
staller password.