Digital in-1, Function, Switch – SMA Sunny Boy Control User Manual
Page 112: Name, Din1, Hightext, Lowtext, Frequency, Unit, Gain
Sunny Boy Control
SMA Technologie AG
User Manual
SUNBC-14:NE0206
108
Hardware-Based Configuration
All parameters for the digital and analog input channels can be configured in the
menu items “Setup…Plus I/O…Analog In” and “…Digital In” of the Sunny
Boy Control Plus. But these settings can also be made from a PC using Sunny Data
Control (refer to chapter “8 Data Display and Configuration From a PC”).
[ DIGITAL IN-1 ]
‡Function…
Selecting the function of the digital channel
…Switch
Switch, Trigger Low, Trigger High
---------------Š
Name…
Name of the channel
………+DIn1
HighText…
Text for the “switched on” condition
……………off
LowText…
Text for the “switched off” condition
……………on
Fig. 7.16: Configuration of digital input channels as switches
[ DIGITAL IN-1 ]
Function…
Selecting the function of the digital channel
…Frequency
Frequency, Impulse cont., Impulse daily
---------------Š
Name…
Name of the channel
………+DIn1
Unit…
Measuring unit
………………Hz
Gain…
…………………1
Conversion from “measured value (x) to displayed value (y)“:
Offset…
y = x * (gain) + offset
…………………0
Fig. 7.17: Configuration of digital input channels as counters