Parameters of Profile 2

Symbol Explanation

Comment

Input parameters

Pac

Total system power output

Sum of the “Pac” of all Sunny Boys
(Note: Unit = kW)

+Gi

Module irradiation

Measured with pyranometer or refer-
ence cell

-+Tam

Ambient temperature

Measured with PT100

System constants

+A

Total module surface

Surface of all modules installed

+etaM

Module efficiency

approx. 0.9*etaSTC

Secondary (derived) parameters

+Eac Yield

Derived

from

Pac

+Hi

Irradiation (energy)

Derived from +Gi

+Enom Nominal

(theoretical)

yield

Derived from +Hi and +etaM

Resulting system characteristics


+etaPV System

efficiency

Current output & input power

+PR

Performance ratio

Daily yield at nominal yield

Table 7.21: Parameters of Profile 2

After loading Profile 2, the following variables have to be adjusted to the existing
system configuration.

Gain of Analog input 1: Signal conversion to W/m

2

, default = 150

+A : Module surface, default = 10 m

2

+etaM: Module efficiency, default = 14 %
(usually approx. 0.9*etaM, STC-check module specifications; STC = Standard
Test Conditions)

+Mon1: Adjust tolerances to system performance.

No further settings and adjustments are necessary. All other parameters are calcu-
lated automatically.