SMA Sunny Boy Control User Manual
Page 126

Sunny Boy Control
SMA Technologie AG
User Manual
SUNBC-14:NE0206
122
Parameters of Profile 2
Symbol Explanation
Comment
Input parameters
Pac
Total system power output
Sum of the “Pac” of all Sunny Boys
(Note: Unit = kW)
+Gi
Module irradiation
Measured with pyranometer or refer-
ence cell
-+Tam
Ambient temperature
Measured with PT100
System constants
+A
Total module surface
Surface of all modules installed
+etaM
Module efficiency
approx. 0.9*etaSTC
Secondary (derived) parameters
+Eac Yield
Derived
from
Pac
+Hi
Irradiation (energy)
Derived from +Gi
+Enom Nominal
(theoretical)
yield
Derived from +Hi and +etaM
Resulting system characteristics
+etaPV System
efficiency
Current output & input power
+PR
Performance ratio
Daily yield at nominal yield
Table 7.21: Parameters of Profile 2
After loading Profile 2, the following variables have to be adjusted to the existing
system configuration.
•
Gain of Analog input 1: Signal conversion to W/m
2
, default = 150
•
+A : Module surface, default = 10 m
2
•
+etaM: Module efficiency, default = 14 %
(usually approx. 0.9*etaM, STC-check module specifications; STC = Standard
Test Conditions)
•
+Mon1: Adjust tolerances to system performance.
No further settings and adjustments are necessary. All other parameters are calcu-
lated automatically.