beautypg.com

Failure, Yield output, No communication – SMA Sunny Boy Control User Manual

Page 137: For 24h

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC

-

14

:

NE0206

133

Energy Yield Error: “Yield output xx %”

[ FAILURE ]

[03: WR700-07 ]

Device ID: device model

Yield output…

………………48%

Minimum yield expected compared with the daily system average

Fig. 9.5: Example of energy yield error

The device’s energy yield was below the tolerance.

Device defective or incorrectly installed.

“Energy” tolerance setting is too low (refer to section 6.2.4).

24 Hour Offline Error: “no communication for 24h”

[ FAILURE ]

[03: WR700-07 ]

Device ID: device model

no communication

for 24h

Device could not be reached for a whole day.

Fig. 9.6: Example of offline error

The device has been out of touch for a whole day. Data processing takes place at
00:00 (midnight).

Causes:

Device is defective or incorrectly installed.

Communication is interrupted.

Search for the cause using the function “Diagnostics…Communication”
(refer to section 5.2).