the socket used for the Sunny Boy Control is not only on the same line (or at least on
the same phase) as the other devices. It should also be as close to them as possible.
In case the Sunny Boy Control and the other devices must be connected to different
phases, it may be necessary to install a phase coupler. Phase couplers are available
from SMA and must be installed on site by a qualified technician.
Further information on optimizing the installation is available in section 9.2.2.
If there are other Powerline communication users in your neighborhood, keep a close
eye on the device detection process to make sure that the Sunny Boy Control detects
only devices that are yours. Otherwise, the Sunny Boy Control can be left to run the
device detection automatically. In that case, all detected devices will be automati-
cally confirmed and registered after 60 seconds. After the device detection is com-
pleted, press [ESC] to exit (Fig. 2.7 ), then [ENTER] to confirm (Fig. 2.8).
Automatic Device Detection
The Sunny Boy Control automatically detects all the devices it can access.
[ DETECTION ]
searching for
new devices
Fig. 2.7: Sunny Boy Control searching for new devices
Depending on the number of devices to be detected, this process may take several
minutes. An hourglass appears in the lower-right corner of the display, showing that
the program is active. The serial number of any detected device will be displayed on
the bottom line.
After the detection process is completed, each device found by the Sunny Boy Con-
trol is displayed as follows in sequence.
New device
Type xxxxxxxx
SNo xxxxxxxxx
accept?
Fig. 2.8: New device found by Sunny Boy Control
At this point, compare the serial numbers of the devices found by the Sunny Boy Con-
trol with the serial numbers of your devices. Press
[
ENTER
]
to register a device in the