7.6 “Profile 2” Application
Two default profiles (Profile 1 & Profile 2) can be loaded from
“Setup…Plus I/O…Plus-Function”. “Profile 1” deactivates the Plus functions and
resets all Plus settings to their factory defaults. “Profile 2” requires only an external
sensor (pyranometer or reference cell) to acquire module irradiation data. The follow-
ing is an application example for “Profile 2”.
Powerline
PV panel
°C
Ambient temperature
Module insolation
Sunny Boy
Control Plus
Pac
+Gi
+Tam
Betrieb
Ope
ration
Erdschluss
Earth
Fault
Störung
Failure
Photovolta
ik-Stri
ngwec
hselric
hter
Photovo
ltaic str
ing invert
er
SWR
1100E
PAC 1273
W
Fig. 7.24: Input parameters for “Profile 2”
The current system efficiency (+etaPV) and the daily energy yield (+PR) can be ob-
tained by comparing and further computing the panel irradiation and the power out-
put of the Sunny Boy inverters. These calculations require the system constants “+A”
(the module surface) and “+etaM” (the module efficiency).