ANALOG IN:

DB25 connector

Overvoltage protection:

±15 – ±35 V

Input coupling:

DC, 1 MOhm

6 analog inputs:

Measuring range (accuracy):

-10 – +10 V

(0.1 %)

-5 – +5 V

(0.3 %)

-1 – +1 V

(0.3 %)

-500 – +500 mV

(0.3 %)

-100 – +100 mV

(0.3 %)

-50 – +50 mV

(0.3 %)

-20 – +20 mV

(0.3 %)

-10 – +10 mV

(0.5 %)

-20 – +20 mA

(0.2 %)

2 analog inputs

PT100:

4-wire

measuring

Measuring range:

-40 – +140 °C (1 %)

A/D converter

Resolution: 16 bit