5.3 Communication Function

The “Communication” function is useful for diagnosing the communication with the
Sunny Boy inverters and analyzing data transmission failures. First, press [ENTER] to
select an inverter to be diagnosed.

[COMMUNICATION ]

„01…WR700-08

Device ID... device model / serial number

„02…WR700-08

„03…WR700-07 Š

„04…WR700-07

Fig. 5.13: Device selection screen

During the communication test the Sunny Boy Control interrupts its normal operation
and instead sends data requests to the selected Sunny Boy. The test results are dis-
played as follows:

[01:COMMUNICAT.]

Device ID: communication

‡OK…………………………99%

Percentage of correctly transmitted data packets

Packets………10233

Requested data packets

Errors………………12Š

Faulty or ignored data packets

Level…………1000mV

Signal level for Powerline communication

Fig. 5.14: Communication test

The continuously displayed information comprises the percentage of correctly trans-
mitted packages (based on the last 20 data packets), the number of requested data
packets, the number of errors, and (for Powerline communication only) the signal
level.