6.2.2 Timing

[ Timing ]

Cmd Timeout…………

…………………4000ms

Max.timespan waiting for an answer from a device

Cmd. Retries……Š

………………………1time

Number of packet repeats in case of an error

Data Buffer…

………………2Cycles

Number of cycles for buffering the measuring data.

Fig. 6.4: Setting the timing

These parameters are tuned to work ideally with PV systems comprised of
Sunny Boy inverters. For configurations that better suit Sunny Team or
Sunny Island systems, refer to the corresponding user manuals.

6.2.3 Online Info

The “Channel Cnt.” information in the “ONLINE-INFO” menu tells you the total
number of channels that appear in the Online Info (refer to section 4.2).

[ ONLINE-INFO ]

‡Channel Cnt.…

…………………4

Number of channels displayed in Online Info

---------------Š

„Chan. Select.

Selection of channels (see below)

Fig. 6.5: Configuring “Online-Info”

To configure “Online-Info”, select the menu item “Chan. Selct.”, and then press
[ENTER] to confirm. You will obtain a list of all registered devices.