4.3.1 “Total Plant” function

[ TOTAL PLANT ]

‡Pac…

…………………0W

Total system power output

E-today… Š

……………---kWh

Daily energy yield

E-total…

……………---kWh

Total energy yield

DATA STORAGE

Energy Values…

…………………0days

Timespan of daily values stored

DAS Data…

…………………0cycles

Number of measuring-channel cycles

Detected…

…………………0devices

Number of detected inverters

Registered…

…………………0devices

Number of registered inverters

Online…

…………………0devices

Number of inverters currently online

Fig. 4.5: “Total Plant” function

The “Total Plant” function gives an overview of the operating condition of your
entire system.

In addition to the total (E-total) and daily (E-today) energy yields of the system, you
can display the current data storage settings of the Sunny Boy Control.

Depending on the configuration, the storage capacity for the daily energy values is
about one year. It is therefore recommended that you back up the acquired data at
least once a year in order to avoid data loss due to insufficient memory. The maxi-
mum number of the measuring-channel cycles depends on the number of defined
measuring channels. Refer to Table 10.1: “Number of daily measuring intervals” for
a detailed calculation.