beautypg.com

2 switching contact – SMA Sunny Boy Control User Manual

Page 47

background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC-14:NE0206

43

3.5.2 Switching Contact

The switching contact is intended to operate an external load according to the load
and time management settings of the Sunny Boy Control. The default switch position
can be changed in the menu “Setup…Interfaces…Relais out…
Switch Contact

” (see section 6.3.3).

Default switch position of

the switching contact

Sunny Boy Control

operating condition

Switching

Contact 2-1

Power failure

Contact 2-1 (pin 2)

Contact 2-1

Normal operation

Contact 2-1 (pin 2)

Contact 2-1

Time/load event

Contact 2-2 (pin 4)

Contact 2-2

Power failure

Contact 2-1 (pin 2)

Contact 2-2

Normal operation

Contact 2-2 (pin 4)

Contact 2-2

Time/load event

Contact 2-1 (pin 2)

Table 3.7: Switch positions of switching contact

To switch an external load connected to the switching contact, an additional relay is
required.

This manual is related to the following products: