beautypg.com

SMA Sunny Boy Control User Manual

Page 64

background image


Sunny Boy Control

SMA Technologie A

G

User Manual

SUNBC-14:NE0206

60

Displayed message

Type of event

Explanation

System messages

Startup

Status

Device was switched on/system was started up.

Time changed

Status

Time or date was changed by user.

Failure conf.

Status User

acknowledged

error or warning message.

reset diagnosis

Status

Diagnostic data was manually reset.

System Reset

Warning

System was restarted after a failure.

Device-related messages

Device Failure

Warning

Device reported a failure.

Yield

Error

Device yield is below tolerance.

Isolation Res.

Warning

Insulation resistance is low.

SAFETY! Iso.Res.

Error

Insulation resistance is too low.

Communication monitoring

CommSpot20

Warning

Short interruption of communication

Offline

Warning

Device cannot be reached.

Communication

Error

Long interruption of communication

24h Offline

Error

Device could not be reached for at least 24 hours.

Fax/e-mail-related messages

RI Plant-Info

Status

System information was sent.

RI Error/War.

Status

Error/warning report was sent.

RI Transmission

Warning Transmission

failed.

RI Transmission

Error Transmission

could not be initiated.

Monitoring messages (Sunny Boy Control Plus)

Monitor.

Warning

Falling short of tolerance for warnings.

Monitor. >MAX

Warning

Exceeding tolerance for warnings.

Monitor.

Error

Falling short of tolerance for errors.

Monitor. >MAX

Error

Exceeding tolerance for errors.

Table 5.1: Event messages of the Sunny Boy Control

This manual is related to the following products: